get_read_frame
Tobias Müller, M. Eng edited this page 5 years ago

📜 Table of Contents


get_read_frame

Definition
def get_read_frame(self, object_id):
Description

The "get_read_frame" method is used to encode a byte-frame for a 'read'-instruction. It can only be used with a known Object_ID, otherwise it will raise a Value_Error. It returns a bytearray of the frame.

Arguments

The "self" argument is pointing to the object, which calls the method.

The "object_id" is an info or parameter number, which you want to read out.

Info-Object_ID:

_info_battery_voltage                 = 3000
_info_battery_temperature             = 3001
_info_battery_charge_current          = 3005
_info_battery_voltage_ripple          = 3006
_info_state_of_charge                 = 3007
_info_number_of_battery_elements      = 3050
_info_input_voltage                   = 3011
_info_input_current                   = 3012
_info_input_frequency                 = 3084
_info_input_power                     = 3138
_info_output_voltage                  = 3021
_info_output_current                  = 3022
_info_output_frequency                = 3085
_info_output_power                    = 3139
_info_operating_state                 = 3028
_info_boost_active                    = 3019
_info_state_of_inverter               = 3049
_info_state_of_transfer_relay         = 3020
_info_state_of_output_relay           = 3030
_info_state_of_aux_relay_1            = 3031
_info_state_of_aux_relay_2            = 3032
_info_state_of_ground_relay           = 3074
_info_state_of_neutral_transfer_relay = 3075
_info_state_of_remote_entry           = 3086

Parameter-Object_ID:

_para_maximum_current_of_ac_source    = 1107
_para_battery_charge_current          = 1138
_para_smart_boost_allowed             = 1126
_para_inverter_allowed                = 1124
_para_type_of_detection_of_grid_loss  = 1552
_para_charger_allowed                 = 1125
_para_charger_uses_only_power_from_ac = 1646
_para_ac_output_voltage               = 1286
_para_inverter_frequency              = 1112
_para_transfer_relay_allowed          = 1128
_para_limitation_of_the_power_boost   = 1607
_para_remote_entry_active             = 1545
Return Value

Type -> bytearray

Example Code
>>> # create an object of the Xcom-API-Class
>>> Object = Xcom_API()
>>> 
>>> # call the Method 'get_read_frame'
>>> Byte_Frame = Object.get_read_frame(Xcom_API._info_battery_voltage)
>>> 
>>> # print Byte_Frame
>>> print(Byte_Frame)
    bytearray(b'\\xAA\\x00\\x01\\x00\\x00\\x00\\x65\\x00\\x00\\x00\\x0A\\x00\\x6F\\x71\\x00\\x01\\x01\\x00\\xB8\\x0B\\x00\\x00\\x01\\x00\\xC5\\x90')